Structural Fire Fighting Clothing
Specialist Fire Fighter's Clothing
Protective Clothing
Jackets
Sweats, T's & Polos
Accessories > Gas monitor > ALTAIR-4X
Tel: +44 (0)1332 758 510


Product
Specification
Materials
Sizing
Aftercare
Standards
Altair-4X
- reliable multi-gas detector
- measures O2, H2S, CO and combustible gas.
- one of the most compact multi-gas detectors available
- extremely durable rubberized housing - survived 6m drop test onto concrete
- large glove friendly buttons
- the InstantAlert alarm allows the user to manually activate the detector’s alarm system - a standard feature across the ALTAIR 4 range
- high contrast display
- new sensor technology using MSA XCell sensors that double the industry average
-
MSA XCell Sensors- Standard response and clear times less than 15 seconds
-
Outstanding signal stability and repeatability under changing or extreme environmental conditions
-
Typical life greater than 4 years
-
End-of-sensor-life indication reducing instrument downtime and reducing inventory
-
MotionAlert feature -triggers an alarm if the user remains motionless for 20 seconds, indicating possible "man down"
-
InstantAlert feature- allows users to manually activate all alarms to alert others to a potentially hazardous situation
-
Triple alarm system- clear visual, audible and vibration alarm notification
-
Large LCD- clear, easy and concise readings at a glance
-
24 hour bump-test checkmark- confirms the detector recently passed a gas response check
-
Rugged rubberised housing- withstands 6 m drop
-
IP 67 rated by a 3rd party -resists water and dust ingress
-
Li-polymer battery- optimum usage time (24 hrs) with minimum charging time means you can buy fewer instruments to cover long shifts
-
Glow-in-the-dark case (optional) allows high visibility, increasing the safety at confined spaces, mining and other dark environments
-
QuickCheck Test Station compatible- allows automatic bump testing of unit with a simple PASS or FAIL indication, helping to reduce human error. All test records are stored and can be retrieved as needed using MSA Link Software
-
MSA Link Software-compatible -when connected to MSA Link Software, all stored records can be accessed. Print capability for calibration reports, alarm set point changes etc. is offered in multiple languages
-
Event log/data logRecords up to 500 events for a quick overview of calibration records and alarms. If more details are required, a full data log can be assessed
-
Ergonomic design with large rubberised buttons ensures easy operation, even with gloves
-
MSA XCell Sensors- Lower cost of ownership due to less gas required (faster calibrationand bump check times) and longer sensor life
-
3-year standard warranty (up to 4 years, optional)
-
GALAXY System compatible- allows for automatic testing, calibration, and record keeping for up to 10 units simultaneously, helping to reduce human error
- Auto calibration- saves time and calibration gas by calibrating all sensors simultaneously
CSA Class I, Division 1, Groups A, B, C & D
ETL Class II, Division 1, Groups E, F & G/ Class III, Division 1
Europe:
Directive 94/9/EC (ATEX):
II 1G Ex ia IIC T4 (Zone 0 with no combustible sensor installed)II 2G Ex ia d IIC T4 (Zone 1 with combustible sensor installed)/CE 0080
Australia/New Zealand:
TestSafe Australia Ex ia s IIC T4 (Zone 0)
IECEx: TestSafe Australia Ex ia IIC T4
(Zone 0 with no combustible sensor installed)
Ex ia d IIC T4
(Zone 1 with combustible sensor installed)