Structural Fire Fighting Clothing
Specialist Fire Fighter's Clothing
Protective Clothing
Jackets
Sweats, T's & Polos
Fire Fighters Clothing > Structural Fire Fighting Clothing > 720-725-Combi Jacket & Salopettes





- Waist length jacket with full zip opening
- High collar fully lined with throat closure tab
- 3 piece set in sleeves with underarm gusset
- Articulated elbows with wadded patches
- 1 vertical entry pocket inside cover flap
- 1 internal poachers pocket
- Self fabric shoulder reinforcement with wadding
- Velcro® fastening shaped radio pocket on breast*
- Torch/monitor loop on breast
- Action back pleats into waist band
- Knitted cuffs with thumb loop
- Anti-wicking storm cuffs with drainage mesh
- Velcro tab wrist closure
- FR drainage mesh into waist hem
725 Salopettes
- Lower chest height
- Elasticated braces with quick release buckles
- Front zip fastening with cover flap
- Velcro® fastening side waist tabs
- 2 side hip pockets
- Articulated knees for easy movement
- Kevlar knee patches with internal wadding
- Anti-wicking splash guard at plain ankle hems
- FR drainage mesh into ankle hems
Face Fabrics for Fire Fighting Gaments
Kermel HTA Ripstop
Kermel A90
PBI Gold Ripstop
PBI Gold Matrix
PBI Gold Twill
PBO Millennia Light
Moisture/Thermal Lining Barriers
Tritec
TenCate Tecashield CX140
TenCate Tecashield CZ703

Moisture barriers are essentially constructed using a waterproof, breathable membrane laminated to an inherently fire retardant spun bonded non-woven or knitted substrate. There is a variety of types of membrane ranging from PTFE through FR polyester to FRpolyurethanes and these barriers are all completely waterproof and provide good water vapour transmission rates for breathability.
FlamePro® garments use a range of structures designed to meet the specific requirements of the end user. All these structures exceed EN469 requirements and in some cases are tailored to meet the very highest thermal properties available.
Firefighting Tunics & Combi Jackets
| Label | S | M | L | XL | XXL | XXXL |
| Chest cm | 92 - 100 | 100 -108 | 108 - 116 | 116 - 124 | 124 - 132 | 132 - 140 |
| Height: short | 162 - 170 | 162 - 170 | 162 - 170 | 162 - 170 | 162 - 170 | 162 - 170 |
| Height: regular | 170 - 184 | 170 - 184 | 170 - 184 | 170 - 184 | 170 - 184 | 170 - 184 |
| Height: tall | 184 - 192 | 184 - 192 | 184 - 192 | 184 - 192 | 184 - 192 | 184 - 192 |
| Height: extra tall | > 192 | > 191 | > 192 | > 192 | > 192 | > 192 |
please note: all sizes in centimetres
Firefighting Trouser & Salopettes
| Label | S | M | L | XL | XXL | XXXL |
| Waist cm | 72 -80 | 80 - 88 | 88 - 96 | 96 - 104 | 104 - 112 | 112 - 120 |
| Short: inside leg | 74 | 74 | 74 | 74 | 74 | 74 |
| Regular: inside leg | 79 | 79 | 79 | 79 | 79 | 79 |
| Tall: inside leg | 84 | 84 | 84 | 84 | 84 | 84 |
please note: all sizes in centimetres
SIZING SETS AVAILABLE ON REQUEST
Coveralls
| Label | S | M | L | XL | XXL | XXXL |
| To fit chest | 92 - 100 | 100 - 108 | 108 - 116 | 116 - 124 | 124 - 132 | 132 -140 |
|
Height: |
162 - 170 | 162 - 170 | 162 - 170 | 162 - 170 | 162 - 170 | 162 - 170 |
| Regular | 170 - 184 | 170 - 184 | 170 - 184 | 170 - 184 | 170 - 184 | 170 - 184 |
| Tall | 184 - 192 | 182 - 192 | 182 - 192 | 182 - 192 | 182 - 192 | 182 - 192 |
| XTall | > 192 | > 192 | > 192 | > 192 | > 192 | > 192 |
please note: all sizes in centimetres
- SIZING SETS ARE AVAILABLE FOR ALL FIRE KIT
- XXL & XXXL SIZES +10%; XXXXL + 15%;
- QUOTATIONS GIVEN FOR SPECIAL MEASURES
Note - Sizing & Fit
A fire fighting suit is designed predominantly to protect the wearer from heat and flame but other factors must be taken into consideration when deciding what the correct fit is for the wearer. The high thermal values incorporated into the suits means that it is essential that the fit is not too tight; encouraging an air flow between the body and the suit will help to reduce the heat build-up from the body, particularly when hard physical work is being undertaken. Please take this into account when measuring up.
Shirts
| Label | S | M | L | XL | XXL | XXXL |
| To fit chest | 90 - 96 | 96 - 104 | 104 - 110 | 110 - 116 | 116 - 122 | 122 - 128 |
please note: all sizes in centimetres
Trousers
| Label | 76 | 82 | 88 | 94 | 100 | 106 | 112 | 116 |
| To fit waste " | 30 | 32 | 34 | 36 | 38 | 40 | 42 | 44 |
| Short (inside leg ") | 29 | 29 | 29 | 29 | 29 | 29 | 29 | 29 |
| Regular (inside leg ") | 31 | 31 | 31 | 31 | 31 | 31 | 31 | 31 |
| Tall (inside leg ") | 33 | 33 | 33 | 33 | 33 | 33 | 33 | 33 |
please note: all sizes in inches


FlamePro (UK) Ltd would be happy to advise on any aspect of care.
Countries within the European Union conform to a series of standards carrying the prefix EN and these standards are developed and published by the European Committee CEN/TC162 - www.bsi-global.com/en. This committee is responsible for determining performance criteria under which all products designed by FlamePro are manufactured. For fire protection these standards include:
EN 470-1:1995 Protective clothing for use in welding and allied processes;